5645 l
| States Not Applicable: | Replaced By: |
| TX | Not Applicable |
| State Exceptions to the National Code: | |
| AR,
|
|
| Established: | Retained: |
| Date Unknown | Not Applicable |
| Discontinued: | NCCI Schedule and Group: |
| Not Applicable | Schedule 27, Group 274 |
PHRASEOLOGY CARPENTRY—DETACHED ONE OR TWO FAMILY DWELLINGS
(N/A OR, VA)
| Note: |
Includes garages constructed in connection with the dwellings. |
NAICS Code(s):
(For reference only. Not to be used for classification of risks for workers compensation purposes.)
236116—New Multifamily Housing Construction (except Operative Builders)
Description:
When all of the carpentry work in connection with the construction of a private residence is performed by employees of the same contractor, the work is assigned to Code 5645. This includes the construction and erection of the sill, rough framework, rough floor, studs, joists, rafters, roof deck, all types of roofing materials, sidewall sheathing, siding, doors, wallboard installation, lathing, windows, stairs, finished flooring, cabinet installation, fencing, decking and all interior wood trim.
Carpentry repair or remodeling of private residences is also assigned to Code 5645. To qualify for Code 5645, carpentry repair or remodeling operations of an interior or exterior nature must take place along with some framing or structural carpentry renovation of the premises that would ordinarily be assigned to Code 5645. When these conditions occur, the insured is performing operations that are analogous to the construction of a private residence, and Code 5645 is assigned to all carpentry operations in connection with the repair or renovation project. Merely performing singular operations such as repairing or replacing cabinets or installing wallboard does not constitute work to be classified to Code 5645. These singular repair operations are assigned to the appropriate classifications representing their specific trades. However, when activities of this nature take place in connection with operations that involve some framing or structural renovation of the dwelling, Code 5645 must be assigned to these specialty operations.
Code 5645 must be applied to the installation of cabinets or interior trim carpentry work in lieu of Code 5437—Carpentry—Installation of Cabinet Work or Interior Trim when employees of the same carpentry contractor perform any other carpentry operations at the same job or location.
Code 5645 is also assigned to carpentry operations on residential structures in connection with building raising or moving operations. When no separation of payroll exists, the payroll for the entire building raising or moving operation must be assigned to Code 5703 or the highest rated classification applicable, whichever is greater.
Special Conditions:
Extra-Territorial Classification Guidelines
The following material was developed by NCCI to be used as a guide by auditors and underwriters in the determination of premium for contracting (construction risks) with extra-territorial employments where no company guidelines have been established for this purpose. Construction classifications are indicated by the addition of a construction code symbol ( • ) next to the classification code number.
|
When a portion of the operations of a risk is insured in a monopolistic state fund, consider the special rules and requirements that may exist in such cases.
CROSS-REF. IRON OR STEEL: ERECTION: STEEL FRAME—INTERIOR—LIGHT GAUGE STEEL: BY CARPENTRY CONTRACTORS IN CONNECTION WITH THE CONSTRUCTION OF DETACHED ONE- OR TWO-FAMILY DWELLINGS
(N/A VA)
CROSS-REF. SIDING INSTALLATION—ALUMINUM OR VINYL: DETACHED ONE- OR TWO-FAMILY DWELLINGS
(N/A VA)
Description:
Aluminum or vinyl siding installation and/or light-gauge interior or exterior steel frame erection is assigned by analogy to Code 5645 provided that these operations are performed on detached one- or two-family dwellings.
Related Operations Not Classified to Code 5645:
|